Kia Forte: Evaporator Core Replacement - Heater - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Evaporator Core Replacement

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Heater / Evaporator Core Replacement

1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater and blower assembly.
(Refer to Heater -"Heater Unit")
3.
Remove the heater unit lower case (A) after loosening the mounting screws.

4.
Pull out the evaporator core (B) from heater unit.

5.
Install in the reverse order of removal.
  
If you're installing a new heater core, add refrigerant oil (PAG OIL).
Replace the O-rings with new ones at each fitting, and apply a thin coat of refrigerant oil before installing them. Be sure to use the right O-rings for R-134a to avoid leakage.
Immediately after using the oil, replace the cap on the container, and seal it to avoid moisture absorption.
Do not spill the refrigerant oil on the vehicle; it may damage the paint; if the refrigerant oil contacts the paint, wash it off immediately.
Apply sealant to the grommets.
Make sure that there is no air leakage.
Charge the system and test its performance.
Do not interchange the inlet and outlet heater hoses and install the hose clamps securely.
Refill the cooling system with engine coolant.
Heater Core Replacement
1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower assembly. (Refer to Heater -"Heater Unit") ...

Temperature Control Actuator Description
The heater unit includes mode control actuator and temperature control actuator. The temperature control actuator is located at the heater unit. It regulates the temperature by the proced ...

See also:

Specifications
Transaxle type M6CF3-1 Engine type Gasoline 1.8 MPI / Gasoline 2.0 GDI 4/5DR 2DR Gear ratio 1st 3.308 3.615 ...

Installation
   WCS(Weight Classification System) is utilizing a robust weight measuring technology. Thus, if any of the following condi ...

Variable Charge Motion Actuator (VCMA) Specification
Motor Item Specification Coil Resistance (Ω) 3.4 ~ 4.4 [20°C(68°F)] Position sensor Item Specification Coil Resis ...

Copyright © www.kifomanual.com 2014-2024