Kia Forte: Inspection - Back-up Lamp Switch - Manual Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Manual Transaxle System / Back-up Lamp Switch / Inspection

1.
Remove the air cleaner assembly.
(Refer to Engine Mechanical System - "Air Cleaner")
2.
Remove the battery and battery tray.
(Refer to Engine Electrical System - "Battery")
3.
Disconnect the back up lamp switch connector (A).

4.
Check the continuity between no. 1 and 2 terminals of backup lamp switch. When the shift lever is in reverse, there should be continuity.

Specification
Item  Specification Current voltage 13V Working voltage  DC 10~15V Operating force 3.0kg Max Voltage ...

Replacement
1. Remove the air cleaner assembly. (Refer to Engine Mechanical System - "Air Cleaner") 2. Remove the battery and battery tray ...

See also:

Variable Intake Solenoid (VIS) Valve Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable. 2. Disconnect the variable intake solenoid valve connector ( ...

Tail Gate Assembly Component Location
(5Door) 1. Tail gate assembly ...

Weight Classification System (WCS)
WCS is intended to detect the occupant’s physique in order to determine whether the passenger airbag should be suppressed or deployed. WCS classifies the front passenger side seat by measurin ...