1. |
Remove the door switch (A) after loosening the bolt.
|
Canister Installation
1.
Installation is the reverse of removal.
Canister installation bolt/nut:
19.6 ~ 29.4 N.m (2.0 ~ 3.0 kgf.m, 14.5 ~ 21.7 lb-ft)
...
Positive Crankcase Ventilation (PCV) Valve Installation
1.
Installation is reverse of removal.
PCV Valve installation:
1.96 ~ 2.94 N.m (0.2 ~ 0.3 kgf.m, 1.45 ~ 2.17 lb-ft)
...
Spark Plug Specification
Item
Specification
Type
SILZKR7B11
Gap
1.0 ~ 1.1
(0.0394 ~ 0.0433)
...