Kia Forte: Compressor Installation - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Compressor Installation

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Air Conditioning System / Compressor Installation

1.
Make sure the compressor mounting bolt with the correct length is screwed in. Tighten the mounting bolts (A) with the specified tightening order.

Tightening torque :
19.6 ~ 33.3 N.m (2.0 ~ 3.4 kgf.m, 14.5 ~ 24.6 lbf.ft)

[Gamma engine]

[Nu engine]

2.
Install in the reverse order of removal.
A.
If you install a new compressor, drain all the refrigerant oil from the removed compressor and measure its volume. Subtract the volume of drained oil from the original compressor oil capacity. The result is the amount of oil you should drain from the new compressor (through the suction fitting)
B.
Replace the O-rings with new ones at each fitting, and apply a thin coat of refrigerant oil before installing them. Be sure to use the right O-rings for R-134a to avoid leakage.
C.
To avoid contamination, do not return the oil to the container once dispensed, and never mix it with other refrigerant oils.
D.
Immediately after using the oil, replace the cap on the container and seal it to avoid moisture absorption.
Compressor Removal
1. If the compressor is marginally operable, run the engine at idle speed, and let the air conditioning work for a few minutes, then shut the engine off. ...

Compressor Inspection
1. Check the plated parts of the disc & hub assembly (A) for color changes, peeling or other damage. If there is damage, replace the clutch set. ...

See also:

Sunvisor
Use the sunvisor to shield direct light through the front or side windows. To use the sunvisor, pull it downward. To use the sunvisor for the side window, pull it downward, unsnap it from the br ...

Description
The Evaporative Emission Control System prevents fuel vapor stored in fuel tank from vaporizing into the atmosphere. When the fuel evaporates in the fuel tank, the vapor passes through vent h ...

Basic Troubleshooting
Basic Troubleshooting Guide Customer Problem Analysis Sheet Basic Inspection Procedure Measuring Condition of Electronic Parts' Resistance The measured resistance at hig ...

Copyright © www.kifomanual.com 2014-2025