Kia Forte: Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications

Direct control VFS[T/CON]
▷ Control type : Normal low type
Control Pressure kpa (kgf/cm², psi)
9.81 ~ 500.14 (0.1 ~ 5.1,1.42 ~ 72.54)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

Torque Converter Control Solenoid Valve (T/CON_VFS) Description
Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque converter. ...

Torque Converter Control Solenoid Valve (T/CON_VFS) Circuit Diagram
...

See also:

Tail Gate Weatherstrip Replacement
(5Door) 1. Remove the tail gate weatherstrip (A).    ...

Seat Belt Switch Inspection
1. Remove the connector from the switch. 2. Check for continuity between terminals. Seat belt condition Continu ...

Windshield Wiper-Washer Switch Installation
1. Install the multifunction switch. 2. Install the clock spring. 3. Install the steering column upper and lowe ...