Kia Forte: Heater & A/C Control Unit (Manual) Components

| Connector Pin Function |
| Connector |
No. |
Description |
Connector |
No. |
Description |
| A |
1 |
Ground |
B |
14 |
Intake actuator (Recirculation) |
| 2 |
Middle - High |
15 |
Sensor signal |
||
| 3 |
Middle - Low |
16 |
Ground |
||
| 4 |
High |
17 |
Illumination (+) (Tail) |
||
| 5 |
Common |
18 |
Sensor REF (+5V) |
||
| 6 |
Low |
19 |
Detent OUT (+) |
||
| B |
1 |
Battery (+) |
20 |
Max blower ON signal |
|
| 2 |
IGN 2 |
21 |
Evaporator temperature sensor (+) |
||
| 3 |
IGN 1 |
22 |
Ambient temperature sensor (+) |
||
| 4 |
HTD |
23 |
PTC relay (PTC only) |
||
| 5 |
Rear defog switch |
24 |
ECV (+) (ECV only) |
||
| 6 |
Mode actuator feedback |
25 |
ECV (-) - ground (ECV only) |
||
| 7 |
Temperature control actuator feedback |
26 |
- |
||
| 8 |
Intake actuator feedback |
27 |
C_CAN (High) |
||
| 9 |
Mode control actuator (Vent) |
28 |
C_CAN (Low) |
||
| 10 |
Mode control actuator (Defrost) |
29 |
- |
||
| 11 |
Temperature control actuator (Cool) |
30 |
Blower ON signal to common |
||
| 12 |
Temperature control actuator (Warm) |
31 |
Ground |
||
| 13 |
Intake actuator (Fresh) |
32 |
Illumination (-) (Rheostat) |
Controller
Heater & A/C Control Unit (Manual) ReplacementInjector Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance between the inject ...
SS-A Solenoid Valve(ON/OFF) Specifications
ON/OFF Solenoid Valve(SS-A, SS-B)
▷ Control type : Normal low type
Control pressure kpa (kgf/cm², psi)
490.33(5.0, 71.12)
Internal resistance(Ω ...
Crash Pad Upper Panel Component Location
1. Crash pad upper panel
...