Kia Forte: Line Pressure Control Solenoid Valve Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Line Pressure Control Solenoid Valve Specifications

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Valve Specifications

Direct control VFS[Line Pressure]
▷ Control type : Normal high type
Control Pressure kpa (kgf/cm², psi)
500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1

Line Pressure Control Solenoid Valve Description
line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Valve Circuit Diagram
...

See also:

Description
Burglar Alarm State [B/A State] B/A State Description DISARM 1. In "DISARM" state, no vehicle start inhibition. So, whe ...

Rear Glass Defogger Switch Inspection
1. The rear glass defogger switch inputs can be checked using the GDS. 2. To check the input value of rear glass defogger switch, select ...

IMS Control Switch Inspection
1. With the power seat switch in each position, make sure that continuity exists between the terminals below. If continuity is not as specified, replace the power seat ...

Copyright © www.kifomanual.com 2014-2024