Kia Forte: Temperature Control Actuator Inspection - Heater - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Temperature Control Actuator Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Heater / Temperature Control Actuator Inspection

1.
Turn the ignition switch OFF.
2.
Disconnect the temperature control actuator connector.
3.
Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.
Verify that the temperature control actuator operates to the warm position when connected in reverse.

1. -
2. -
3. Warm position
4. Sensor ground
5. Feedback signal
6. Sensor (+ 5V)
7. Cool position

4.
Connect the temperature control actuator connector.
5.
Turn the ignition switch ON.
6.
Check the voltage between terminal 6 and 7.
Specification
Door position
Voltage (V)
Error detecting
Max. cooling
0.3 ± 0.15
Low voltage : 0.1V or less
Max. heating
4.7 ± 0.15
High voltage : 4.9V or more

It will feedback the current position of the actuator to the controls.
7.
If the measured voltage is not within specification, substitute with a known-good temperature control actuator and check for proper operation.
8.
Replace the temperature control actuator if it is proved that there is a problem with it.
Temperature Control Actuator Description
The heater unit includes mode control actuator and temperature control actuator. The temperature control actuator is located at the heater unit. It regulates the temperature by the proced ...

Temperature Control Actuator Replacement
[Driver's side] 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel. (Refer to Body -& ...

See also:

Intake Air Temperature Sensor (IATS) Description
Intake Air Temperature Sensor (IATS) is included inside Manifold Absolute Pressure Sensor and detects the intake air temperature. To calculate precise air quantity, correction of the air tem ...

AGM Battery Description
AGM battery is used for especially heavy load on the vehicle network depending on equipment and requirements. AGM stands for Absorbent Glass Material Battery; that is absorbent glass fibre fl ...

Blower Motor Replacement
1. Disconnect the negative (-) battery terminal. 2. Disconnect the connector (A) of the blower motor. 3. Remove ...

Copyright © www.kifomanual.com 2014-2026