Kia Forte: Valve Body Removal - Hydraulic System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Valve Body Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Hydraulic System / Valve Body Removal

1.
Disconnect the negative (-) battery cable.
2.
Remove the air cleaner assembly and air duct.
(Refer to Engine Mechanical System - "Air cleaner")
3.
Remove the under cover (A).

Tightening torque:
6.9 ~ 10.8 N.m (0.7 ~ 1.1 kgf.m, 5.1 ~ 8.0 lb-ft)

4.
Replace new gasket and the plug after draining the automatic transaxle fluid by removing the drain plug.
(Refer to Hydraulic System - "Fluid")
5.
Remove the air breather hose (A).
6.
Remove the valve body cover (B).

Tightening torque:
11.8 ~ 13.7 N.m (1.2 ~ 1.4 kgf.m, 8.7 ~ 10.1 lb-ft)

7.
Remove the plate and the detent spring (A) after removing the bolt.

Tightening torque:
11.8 ~ 15.7 N.m (1.2 ~ 1.6 kgf.m, 8.7 ~ 11.6 lb-ft)

8.
Remove the bolt (3ea) after disconnecting the solenoid valve (B) connector and the oil temperature sensor connector (A).

Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

9.
Remove the valve body assembly (A).

Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

Valve Body Components Location
1. Pressure Controle Valve(PCV) adjust screw 2. Solenoid valve 3. Oil temperature sensor 4. Accumulator 5. Low & Reverse Brake(LR/B) pressure flow hole 6. Underdrive ...

Valve Body Installation
1. Install in the reverse order of removal.    After replacement or reinstallation procedure of ...

See also:

Operation
Function Of Safety Power Window When all door (Front, Rear) power window auto-up switch is operated, safety function is activated. 1. Safety function condition ...

Inspection (With GDS)
1. Check BCM input/output specification of multifunction switch using the GDS. If the specification is abnormal, replace the lamp or wiper switch. ...

Purge Control Solenoid Valve (PCSV) Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable. 2. Disconnect the purge control solenoid valve connector (A) ...