1. |
Disconnect the negative (-) battery terminal.
|
2. |
Remove the cluster fascia panel.
(Refer to Body - "Cluster Fascia Panel")
|
3. |
Remove the cluster (A) from the housing after removing 4 screws.
|
4. |
Disconnect the cluster connecter (A) and then remove the cluster
(B).
|
Inspection
[EVAP. Leakage Test]
1.
Select "Evap. Leakage Test".
2.
Proceed with the test according to the screen introductio ...
General Inspection
After or before servicing the EPS system, perform the troubleshooting
and test procedure as follows. Compare the system condition with normal condition
in the table below and if abnormal symp ...
Limp Home Function
1.
Limp Home By Tester
If the ECM detects the fault of the Immobilizer or transponder,
the ECM will allow limp home function of the immobilizer. Limp home
is o ...