1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the mode control actuator connector.
|
3. |
Verify that the mode control actuator operates to the defog mode
when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the mode control actuator operates to the vent mode
when connecting in the reverse.
|
4. |
Connect the mode control actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminal 6 and 5.
Specification
It will feedback the current position of the actuator to the controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good mode control actuator and check for proper operation.
|
8. |
Replace the mode control actuator if it is proved that there is
a problem with it.
|
Shift Lever Removal
1.
Remove the floor console assembly.
(Refer to Body - "Floor Console")
2.
Remove the air duct.
3.
...
Circuit Diagram
...
Thermostat Removal and Installation
Disassembly of the thermostat would have an adverse effect, causing
a lowering of cooling efficiency. Do not remove the ...