Kia Forte: Intake Actuator Inspection - Blower - Heating,Ventilation, Air Conditioning - Kia Forte TD 2014-2018 Service ManualKia Forte: Intake Actuator Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Heating,Ventilation, Air Conditioning / Blower / Intake Actuator Inspection

1.
Turn the ignition switch OFF.
2.
Disconnect the intake actuator connector.
3.
Verify that the intake actuator operates to the recirculation position when connecting 12V to terminal 3 and grounding terminal 7.

1. -
2. -
3. Fresh
4. Sensor (+ 5V)
5. Feedback
6. Sensor Ground
7. Recirculation

4.
Connect the intake actuator connector.
5.
Turn the ignition switch ON.
6.
Check the voltage between terminal 6 and 7.
Specification
Door position
Voltage (V)
Error detecting
Fresh
0.3 ± 0.15
Low voltage : 0.1V or less
Recirculation
4.7 ± 0.15
High voltage : 4.9V or more

7.
If the intake actuator dones not operate well, substitute with a known-good intake actuator and check for proper operation.
8.
Replace the intake actuator if it is proved that there is a problem with it.
Intake Actuator Description
The intake actuator is located at the blower unit. It regulates the intake door by the signal from the control unit. Pressing the intake selection switch will shift between recirculation and ...

Intake Actuator Replacement
1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing. (Refer to Body -"Glove Box Housing") ...

See also:

Sunroof Glass Replacement
   • Put on glove to protect your hands. 1. Close ...

Hood Assembly Component Location
1. Hood assembly ...

Canister Close Valve (CCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the CCV connector. 3. Measure resistance between the CCV termina ...

Copyright © www.kifomanual.com 2014-2024