Kia Forte: CVVT Oil Control Valve (OCV) Removal - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: CVVT Oil Control Valve (OCV) Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / CVVT Oil Control Valve (OCV) Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...

See also:

Underdrive Brake Control Solenoid Valve(UD/B_VFS) Specifications
Direct control VFS[UD/B] ▷ Control type : Normal high type Control Pressure kpa (kgf/cm², psi) 500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42) Current value(mA) ...

Hood Assembly Component Location
1. Hood assembly ...

Removal
1. Engine cover. (Refer to Engine Mechanical System - "Engine cover") 2. Air cleaner assembly and air duct. (Refe ...