Kia Forte: Variable Intake Solenoid (VIS) Valve Removal - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Variable Intake Solenoid (VIS) Valve Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / Variable Intake Solenoid (VIS) Valve Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the variable intake solenoid valve connector (A).
3.
Disconnect the vacuum hoses (B) from the valve.
4.
Remove the installation nut, and then remove the valve from the surge tank.

Variable Intake Solenoid (VIS) Valve Inspection
1. Turn the ignition switch OFF. 2. Disconnect the VIS valve connector. 3. Measure resistance between VIS valve ...

Variable Intake Solenoid (VIS) Valve Installation
   • Install the component with the specified torques. • ...

See also:

Precautions
General Precautions Please read the following precautions carefully before performing the airbag system service. Observe the instructions described in this manual, or the airba ...

Smart Key
Smart Key Code Saving 1. Connect the DLC cable of GDS to the data link connector in driver side crash pad lower panel, turn the power on GDS. ...

ESC Control Module Installation
1. Install in the reverse order of removal. 2. Tighten the HECU mounting bolts and nuts to the specified torque. 3. ...