Kia Forte: Heated Oxygen Sensor (HO2S) Specification - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: Heated Oxygen Sensor (HO2S) Specification

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / Heated Oxygen Sensor (HO2S) Specification

HO2S [Bank 1/Sensor 1] (Linear type)
Item
Specification
Heater Resistance (Ω)
2.4 ~ 4.0 [20°C(68°F)]

HO2S [Bank 1/Sensor 2] (Binary type)
A/F Ratio (λ)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (Ω)
Approx. 9.0 [20°C(68°F)]

Heated Oxygen Sensor (HO2S) Description
Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Catalytic Converter. It varies in accordance with the air/fuel ratio. Th ...

Heated Oxygen Sensor (HO2S) Circuit Diagram
(M/T) (A/T) ...

See also:

Ignition Coil Inspection
1. Measure the primary coil resistance between terminals (+) and (-). Standard value: 0.75Ω ± 15% ...

Input Speed Sensor Specifications
▷ Type: Hall effect sensor Operation condition [°C(°F)] ((-)40 ~ 150)) -40 ~ 302 Air gap(mm)in. (1.2 ~ 1.8) 0.0472 ~ 0.0709 Output voltage(V ...

Power Window Switch Inspection
Power Window Main Switch Inspection 1. Disconnect the negative (-) battery terminal. 2. Remove the front door trim. (Refer to Body - ...

Copyright © www.kifomanual.com 2014-2024