Kia Forte: Inhibitor Switch Inspection - Automatic Transaxle Control System - Automatic Transaxle System - Kia Forte TD 2014-2018 Service ManualKia Forte: Inhibitor Switch Inspection

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Inhibitor Switch Inspection

  
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
Power Circuit Inspection
1.
Disconnect the Inhibitor swtich connector.
2.
Ignition KEY "ON"" & Engine "OFF".
3.
Measure voltge between supplied power and ground at inhibitor circuit.

Specification : Approx. 12V

Signal Circuit Inspection
1.
Connect the Inhibitor switch connector.
2.
Ignition KEY "ON" & Engine "OFF".
3.
Measure voltages between each terminal and chassis ground during shift lever changed "P, R, N, D".

Specification : See below "Signal Code Table"

Signal Code Table
 
P
P-R
R
R-N
N
N-D
D
Signal "1"
12V
12V
0
0
0
0
0
Signal "2"
0
12V
12V
12V
0
0
0
Signal "3"
0
0
0
12V
12V
12V
0
Signal "4"
0
0
0
0
0
12V
12V

Inhibitor Switch Circuit Diagram
...

Inhibitor Switch Removal
1. Place the shift lever into the "N" position. 2. Remove the air cleaner. (Refer to Engine Mechanical System - "Air clea ...

See also:

Removal
1. Remove the rear wheel & tire. Tightening torque: 88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft) ...

Auto Defogging Actuator Inspection
1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defoggin ...

Components
...