1. |
Storage State
Sensors are in this state when they first arrive at dealership.
This state is entered by LF request/command only.
Either LF request / command or an automatic exit due to the pressure
will allow an exit from this state.
The transmitter will not transmit RF messages in this state, unless
an LF initiate transmission request is received or an exit due to pressure
triggers an RF response.
The pressure/temperature measurement rate will be every 60 seconds.
If four (4) successive pressure measurements exceeding 25 psi
are recorded, an exit to the Sleep State will occur.
|
2. |
Sleep State
This state is entered by LF request / command, by exiting from
the Rest State following a 15 minute timeout due to no motion
(accelerometer measurement < 10g) or by exiting Storage State due to
pressure.
This state is exited by LF request / command or due to motion
(accelerometer measurement > 10g).
The transmitter will not transmit RF messages in this state, unless
a LF initiate transmission request is received.
|
3. |
Normal Motion State
This state is entered by LF request / command or a return from
an alert condition, or by exiting Sleep State due to motion.
This state is exited by LF request / command, no motion or an
alert condition.
For the first 80 seconds following Sleep State exit, the transmission
rate will be every 16 seconds, the acceleration and pressure measurement
rate will also be at a rate of every 16 seconds for the first 80 seconds
after Sleep State exit.
Following the first 80 seconds after Sleep state exit, the transmission
rate will be every 1 minute.
The acceleration will be measured every 60 seconds and pressure
every 20 seconds following the first 80 seconds after exit from Sleep
State.
The transmitter will transition to the Alert State if the temperature
exceeds 110C or a 20KPa change in pressure is detected between the last
transmitted pressure value and the current measured value.
|
4. |
Rest State
This state is entered by LF request / command or by exiting Normal
Motion State State due to accelerometer measurement < 10g.
This state is exited by LF request / command, due to motion (accelerometer
measurement > 10g) or following a Rest State timeout of 15 minutes with
no motion (accelerometer measurement < 10g) after which it will exist
to the Sleep State.
|
5. |
Alert State
This state is entered by LF request/command or a temperature/pressure
alert condition (exceeding 110C or a 20KPa change in pressure).
This state is exited by LF request / command or automatically
exits once the alert RF transmissions are complete.
In Alert State pressure measurements occur every 4 seconds and
the transmitter will transmit at a 4 second interval for 1 minute.
|
Smart Key Unit Circuit Diagram
...
Component Location
1. Horn switch
2. Horn relay (Engine room compartment)
3. Clock spring
4. Horn
...
Operation
Control Specification
1.
MANUAL Operation
(1)
MANUAL Seat Operation SEAT is to be operated by MANUAL
switch Input of SEAT. SLI ...