Kia Forte: Cooling Fan Description - Cooling System - Engine Mechanical System - Kia Forte TD 2014-2018 Service ManualKia Forte: Cooling Fan Description

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Mechanical System / Cooling System / Cooling Fan Description

[Air conditioning type]
The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
100 ~ 105 (212 ~ 221)
LOW
105 (221) or above
HIGH
45 (28) ≤ V < 80 (49.7)
100 ~ 105 (212 ~ 221)
LOW
105 (221) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
ON
P < 6 (85.3)
All
105 (221) or above
HIGH
6 (85.3) ≤ P < 12 (170.7)
V < 45 (28)
60 ~ 100 (140 ~ 212)
LOW
100 (212) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
12 (170.7) ≤ P < 15.5 (120.5)
V < 45 (28)
-30 ~ 95 (-22 ~ 203)
LOW
95 (203) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
15.5 (120.5) ≤ P
All
-30 (-22) or above
HIGH

[Non-Air conditioning type]
The cooling fan operates in 1 stages (HIGH). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
100 ~ 105 (212 ~ 221) or above
HIGH
45 (28) ≤ V < 80 (49.7)
100 ~ 105 (212 ~ 221) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH

Cooling Fan Components
1. Cooling fan 2. Fan motor 3. Cooling fan shroud 4. Resister ...

Cooling Fan Specifications
Item Specification Fan type PULLER Fan speed control Resistor (HI-LOW-OFF) Air flow rate [㎥/h (yd³/h)] 1,700 (2,22 ...

See also:

Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications
Direct control VFS[T/CON] ▷ Control type : Normal low type Control Pressure kpa (kgf/cm², psi) 9.81 ~ 500.14 (0.1 ~ 5.1,1.42 ~ 72.54) Current value(mA) ...

Air Ventilation Seat Unit Installation
Cushion Blower 1. Install the cushion blower under the bottom of the seat. 2. Install the front seat aseembly. Back Blower ...

Fuel Tank Pressure Sensor (FTPS) Specification
Pressure [kPa (kgf/cm², in H2O) Output Voltage (V) -6.67 (-0.068, -26.8) 0.5 0 2.5 +6.67 (0.068, 26.8) 4.5 ...

Copyright © www.kifomanual.com 2014-2024