Kia Forte: CVVT Oil Control Valve (OCV) Removal - Engine Control System - Engine Control / Fuel System - Kia Forte TD 2014-2018 Service ManualKia Forte: CVVT Oil Control Valve (OCV) Removal

Second generation YD (2014-2018) / Kia Forte TD 2014-2018 Service Manual / Engine Control / Fuel System / Engine Control System / CVVT Oil Control Valve (OCV) Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
3.
Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]

[Bank 1 / Exhaust]

CVVT Oil Control Valve (OCV) Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV termina ...

CVVT Oil Control Valve (OCV) Installation
   • Install the component with the specified torques. • ...

See also:

Front Driveshaft Replacement
1. Loosen the wheel nuts slightly. Raise the vehicle, and make sure it is securely supported. 2. Remove the front wheel and tire (A ...

General Service Information
Protection Of The Vehicle Always be sure to cover fenders, seats, and floor areas before starting work.    The support r ...

Fuel Filter Removal
1. Remove the fuel pump (Refer to “Fuel Pump” in this group). 2. Disconnect the electric pump wiring connector (A) and the fuel sender conn ...

Copyright © www.kifomanual.com 2014-2024