1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the mode control actuator connector.
|
3. |
Verify that the mode control actuator operates to the defog mode
when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the mode control actuator operates to the vent mode
when connecting in the reverse.
|
4. |
Connect the mode control actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminal 6 and 5.
Specification
It will feedback the current position of the actuator to the controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good mode control actuator and check for proper operation.
|
8. |
Replace the mode control actuator if it is proved that there is
a problem with it.
|
Specification
Air Conditioner
Item
Specification
Compressor
Type
6VS14 (MTC) / 6VSE14 (DFATC)
Oil type & Capacity
PAG(FD46XG) 110±10cc
...
Removal
1.
Remove the rear wheel & tire.
Tightening torque:
88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft)
...